Nori Human HE4 ELISA Kit
Price range: $508.00 through $916.00
This ELISA kit is for quantification of HE4 in human. This is a quick ELISA assay that reduces time to 50% compared to the conventional method, and the entire assay only takes 3 hours. This assay employs the quantitative sandwich enzyme immunoassay technique and uses biotin-streptavidin chemistry to improve the performance of the assays. An antibody specific for HE4 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any HE4 present is bound by the immobilized antibody. After washing away any unbound substances, a detection antibody specific for HE4 is added to the wells. Following wash to remove any unbound antibody reagent, a detection reagent is added. After intensive wash a substrate solution is added to the wells and color develops in proportion to the amount of HE4 bound in the initial step. The color development is stopped, and the intensity of the color is measured.
Alternative names for HE4: Human epididymis protein 4, WFDC2, WAP5
This product is for laboratory research use only not for diagnostic and therapeutic purposes or any other purposes.
- Description
- How Elisa Works
- Documents
- Product Citation (0)
- Reviews (0)
Description
Nori Human HE4 ELISA Kit Summary
Alternative names for HE4: Human epididymis protein 4, WFDC2, WAP5
| Assay Type | Solid Phase Sandwich ELISA |
| Format | 96-well Microplate or 96-Well Strip Microplate |
| Method of Detection | Colorimetric |
| Number of Targets Detected | 1 |
| Target Antigen Accession Number | Q14508 |
| Assay Length | 3 hours |
| Quantitative/Semiquantitative | Quantitative |
| Sample Type | Plasma, Serum, Cell Culture, Urine, Cell/Tissue Lysates, Synovial Fluid, BAL, |
| Recommended Sample Dilution (Plasma/Serum) | No dilution for sample <ULOQ; sufficient dilution for samples >ULOQ |
| Sensitivity | 15 pg/mL |
| Detection Range | 78-5000 pg/mL |
| Specificity | Human HE4 |
| Cross-Reactivity | < 0.5% cross-reactivity observed with available related molecules, < 50% cross-species reactivity observed with species tested. |
| Interference | No significant interference observed with available related molecules |
| Storage/Stability | 4 ºC for up to 6 months |
| Usage | For Laboratory Research Use Only. Not for diagnostic or therapeutic use. |
| Additional Notes | The kit allows for use in multiple experiments. |
Standard Curve
Kit Components
1. Pre-coated 96-well Microplate
2. Biotinylated Detection Antibody
3. Streptavidin-HRP Conjugate
4. Lyophilized Standards
5. TMB One-Step Substrate
6. Stop Solution
7. 20 x PBS
8. Assay Buffer
Other Materials Required but not Provided:
1. Microplate Reader capable of measuring absorption at 450 nm
2. Log-log graph paper or computer and software for ELISA data analysis
3. Precision pipettes (1-1000 µl)
4. Multi-channel pipettes (300 µl)
5. Distilled or deionized water
Protocol Outline
1. Prepare all reagents, samples and standards as instructed in the datasheet.
2. Add 100 µl of Standard or samples to each well and incubate 1 h at RT.
3. Add 100 µl of Working Detection Antibody to each well and incubate 1 h at RT.
4. Add 100 µl of Working Streptavidin-HRP to each well and incubate 20 min at RT.
5. Add 100 µl of Substrate to each well and incubate 5-30 min at RT.
6. Add 50 µl of Stop Solution to each well and read at 450 nm immediately.
Background:
Human epididymis protein 4 (HE4) is encoded by WFDC2 gene [1] [2] and belongs to the family of whey acidic four-disulfide core proteins. Currently, the biologic function of HE4 is unknown. HE4 has been shown to be overexpressed in 93% of serous, 100% of endometrioid, and 50% of clear cell ovarian carcinomas.[3] HE4 induces chemoresistance against anti-cancer drugs and activates the AKT and Erk pathways to enhance tumor survival. Human epididymis protein 4 expression in ovarian cancer tissue is associated with a worse prognosis for epithelial ovarian cancer patients.[4] A meta-analysis showed that HE4 is expressed in lung cancer [5] and serum level was a marker of poor prognosis in lung cancer patients.[5] In a study of 233 patients with a pelvic mass, including 67 with epithelial ovarian cancer, HE4 had a higher sensitivity for ovarian cancer detection than cancer antigen 125 (CA 125), 72.9% versus 43.3%, respectively, at a specificity of 95%. Researchers also found HE4 to be elevated in more than half of the ovarian cancer patients who did not have elevated CA 125 levels; therefore, the combination of markers provided slightly improved cancer diagnostic sensitivity for the detection of ovarian cancer. The main established application of HE4 is in post-therapy monitoring of ovarian cancer patients, who had elevated pretreatment levels. In this setting, it complements CA 125 measurement and facilitates follow-up of patients with little or no CA 125 pretreatment elevations. Certain histological types of ovarian cancer (mucinous or germ cell tumors) rarely express HE4, therefore the use of HE4 is not recommended for monitoring of patients with these types of ovarian cancer.
References
- Kirchhoff C, et al. (1990) Int. J. Androl. 13 (2), 155-167.
- Kirchhoff C, et al. (1991) Biol. Reprod. 45 (2), 350-357
- Schummer M, et al. (1999) Gene 238 (2), 375-385
- Lee S, et al. (2017) J. Obstet. Gynaecol. Res. 43 (1), 220-227.
- Zhong H, et al. (2017) Clin. Chim. Acta 470, 109-114.
Be the first to review “Nori Human HE4 ELISA Kit”
You must be logged in to post a review.



























Reviews
There are no reviews yet.