Nori Hamster Myoglobin ELISA Kit

$461.00$832.00

DataSheet   

This ELISA kit is for quantification of MB in hamster. This is a quick ELISA assay that reduces time to 50% compared to the conventional method, and the entire assay only takes 3 hours. This assay employs the quantitative sandwich enzyme immunoassay technique and uses biotin-streptavidin chemistry to improve the performance of the assays. An antibody specific for MB has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any MB present is bound by the immobilized antibody. After washing away any unbound substances, a detection antibody specific for MB is added to the wells. Following wash to remove any unbound antibody reagent, a detection reagent is added. After intensive wash a substrate solution is added to the wells and color develops in proportion to the amount of MB bound in the initial step. The color development is stopped, and the intensity of the color is measured.

Alternative names for myoglobin: MB, Myo

This product is for Laboratory Research Use Only not for diagnostic and therapeutic purposes or any other purposes.

CAT: GR172184 Categories: , Tag:
Clear
View cart

Description

Nori Hamster Myoglobin ELISA Kit Summary

Alternative names for myoglobin: MB, Myo

Alternative names for hamster: golden hamster, syrian hamster

Assay Type Solid Phase Sandwich ELISA
Format 96-well Microplate or 96-Well Strip Microplate
Method of Detection Colorimetric
Number of Targets Detected 1
Target Antigen Accession Number A0A1U7QU54
Assay Length 3 hours
Quantitative/Semiquantitative Quantitative
Sample Type Plasma, Serum, Cell Culture, Urine, Cell/Tissue Lysates, Synovial Fluid, BAL,
Recommended Sample Dilution (Plasma/Serum) No dilution for sample <ULOQ; sufficient dilution for samples >ULOQ
Sensitivity 94 pg/mL
Detection Range 0.47-30 ng/mL
Specificity Hamster MB
Cross-Reactivity < 0.5% cross-reactivity observed with available related molecules, < 50% cross-species reactivity observed with species tested.
Interference No significant interference observed with available related molecules
Storage/Stability 4 ºC for up to 6 months
Usage For Laboratory Research Use Only. Not for diagnostic or therapeutic use.
Additional Notes The kit allows for use in multiple experiments.

 

Standard Curve

Kit Components
1. Pre-coated 96-well Microplate
2. Biotinylated Detection Antibody
3. Streptavidin-HRP Conjugate
4. Lyophilized Standards
5. TMB One-Step Substrate
6. Stop Solution
7. 20 x PBS
8. Assay Buffer

Other Materials Required but not Provided:
1. Microplate Reader capable of measuring absorption at 450 nm
2. Log-log graph paper or computer and software for ELISA data analysis
3. Precision pipettes (1-1000 µl)
4. Multi-channel pipettes (300 µl)
5. Distilled or deionized water

Protocol Outline
1. Prepare all reagents, samples and standards as instructed in the datasheet.
2. Add 100 µl of Standard or samples to each well and incubate 1 h at RT.
3. Add 100 µl of Working Detection Antibody to each well and incubate 1 h at RT.
4. Add 100 µl of Working Streptavidin-HRP to each well and incubate 20 min at RT.
5. Add 100 µl of Substrate to each well and incubate 5-30 min at RT.
6. Add 50 µl of Stop Solution to each well and read at 450 nm immediately.

Background: 

Myoglobin is an iron- and oxygen-binding protein found in the muscle tissue of vertebrates in general and in almost all mammals. It is related to hemoglobin, which is the iron- and oxygen-binding protein in blood, specifically in the red blood cells. In humans, myoglobin is only found in the bloodstream after muscle injury. It is an abnormal finding and can be diagnostically relevant when found in blood. Myoglobin is the primary oxygen-carrying pigment of muscle tissues.[1] High concentrations of myoglobin in muscle cells allow organisms to hold their breath for a longer period of time. Diving mammals such as whales and seals have muscles with particularly high abundance of myoglobin. Myoglobin is found in Type I muscle, Type II A and Type II B, but most texts consider myoglobin not to be found in smooth muscle. Myoglobin is released from damaged muscle tissue (rhabdomyolysis), which has very high concentrations of myoglobin. The released myoglobin is filtered by the kidneys but is toxic to the renal tubular epithelium and so may cause acute renal failure.[2] It is not the myoglobin itself that is toxic (it is a protoxin) but the ferrihemate portion that is dissociated from myoglobin in acidic environments (e.g., acidic urine, lysosomes). Myoglobin is a sensitive marker for muscle injury, making it a potential marker for heart attack in patients with chest pain.[3] However, elevated myoglobin has low specificity for acute myocardial infarction (AMI) and thus CK-MB, cTnT, ECG, and clinical signs should be taken into account to make the diagnosis.

References

  1. Ordway GA, Garry DJ (2004). Exp. Biol. 207 (Pt 20): 3441–6.
  2. Naka T, et al. (2005). Crit Care 9 (2): R90–5.
  3. Weber M, et al. (2005). Biochem. 38 (11): 1027–30.